banner2
Home Products Alat Kualitas Udara Gas Detector ImpulseXP (HONEYWELL)
ImpulseXP (HONEYWELL) PDF Print E-mail
Written by Ray   
Friday, 19 October 2012 23:04

ImpulseXPThe Impulse XP is all about preferences. It delivers advanced, full feature functionality, user configurability with cost effective serviceability for a wide range of toxic gases. Impulse XP delivers all of the above while still
ensuring reliable, accurate readings and no false alarms from radio frequency interference (RFI). In addition Impulse XP provides continuous gas readings, TWA/STEL and two
instantaneous alarms with peak hold facility.

 

General Specification

Standard Specification




Gases Detected Range Level 1 Level 2 STEL TWA
Oxygen (O2 ) 0 to 30% v/v 23.5% v/v 19.5% v/v n/a n/a
Carbon Monoxide (CO) 0 to 999ppm 35ppm 100ppm 400ppm 35ppm
Hydrogen Sulphide (H2 S) 0 to 250ppm 10ppm 15ppm 15ppm 10ppm
Sulphur Dioxide (SO2 ) 0 to 150ppm 2ppm 5ppm 5ppm 2ppm
Chlorine (Cl2 ) 0 to 50ppm 0.5ppm 1ppm 1ppm 0.5ppm
Hydrogen Cyanide (HCN) 0 to 100ppm 5ppm 10ppm 10ppm 5ppm
Nitrogen Dioxide (NO2 ) 0 to 150ppm 3ppm 5ppm 5ppm 3ppm
Ammonia (NH3 ) 0 to 100ppm 25ppm 50ppm 35ppm 25ppm
Ammonia (NH3 ) 0 to 400ppm 35ppm 50ppm 35ppm 25ppm
Hydrogen (H2 ) 0 to 999ppm 100ppm 500ppm n/a n/a
Phophine (PH3 ) 0 to 2ppm 0.3ppm 1ppm 1ppm
Construction
General Serviceable, portable single gas monitor for personal protection against Oxygen and toxic gas hazards
Calibration Time between calibrations is maximised utilizing cell decay compensation facility. The maximum time between calibrations is 12 months#
Operating Life Sensor (replaceable) Minimum of 2 years
Battery (replaceable) 3 years*
Operating Temperature -20°C to +50°C (-4°F to +122°F) (temperature compensated)
Humidity 5-95% RH (non-condensing)
Audible Alarm 95db at 10cm (4in)
Visual Alarm High intensity Red LEDs
Vibrating Alarm Standard
Display Ultra clear backlit LCD displays gas levels & instrument status
Sensor Type Electrochemical (replaceable)
Battery Type Lithium CR2, 3.0V (replaceable)
Diagnostics Self-test of circuitry, battery, LCD, and software. Sensor test using patented Reflex†sensor technology
Environmental
IP Rating IP54 (Minimum)
Intrinsic Safety North America: Class 1, Div 1, Groups A, B, C, D, T4 (UL/cUL)
Europe: EEx ia IIB T4 (CENELEC) II 2G EEx ia IIC T4 (ATEX)
RFI/EMC CE EN50270:1999 and EN55011
Dimensions 93mm (H) x 50mm (W) x 27mm (D)
(3.6” x 2” x 1.1”) excluding clip
Weight Toxic 81.5g (2.8oz)
Oxygen 93.0g (3.3oz)


Last Updated on Friday, 19 October 2012 23:21