banner2
Home Products Alat Kualitas Udara Area Heat Stress - WBGT MicroClimate Analysis HD32 1 (Delta OHM)
MicroClimate Analysis HD32 1 (Delta OHM)

MicroClimate-Analysis-HD32_HD 32.1 INSTRUMENT FOR STUDYING, MEASURING AND CONTROL- LING THE MICROCLIMATE
The Thermal Microclimate HD32.1 instrument is manufactured by Delta Ohm Srl and it allows studying, measuring and controlling the Microclimate in the workplace, in compliance with the following standards:

  • EN ISO 7726: Ergonomics of the thermal environment - Instruments for measuring physical quantities.
  • EN ISO 7730: Moderate Thermal Environments - Determination of the PMV and PPD indices and specification of the condition for thermal comfort.
  • EN ISO 27243: Hot environments. Estimation of the heat stress on working man, based on the WBGT Index (Wet bulb Globe temperature).
  • EN ISO 7933: Ergonomics of the thermal environment - Analytical determination and interpretation of heat stress using calculation of the predicted heat strain.
  • ENV ISO 11079: Evaluation of cold environments - Determination of required clothing insulation (IREQ).
  • EN ISO 8996: Ergonomics of the thermal environment - Determination of metabolic rate.

TECHNICAL SPECIFICATIONS

Instrument
Dimensions (Length x Width x Height) : 220x180x50 mm
Weight : 1100 g (with batteries)
Materials : ABS, Polycarbonate and Aluminium
Display : Backlit, dot matrix 128x64 dots, visible area 56x38mm

Operative conditions
Operative temperature :  -5 … 50°C
Storage temperature : -25 … 65°C
Operative Relative Humidity : 0 … 90% RH non condensing
Protection class : IP64
Instrument uncertainty :± 1 digit @ 20°C

Power supply
Mains adapter (code SWD10) :  12Vdc/1A
Batteries :  Four 1.5V batteries size C-BABY
Autonomy : With temperature and RH probes: 200 hours with 7800mAh alkaline batteries With hotwire probe @ 5m/s: 100 hours with 7800mAh alkaline batteries
Power absorbed (instrument off) : < 45µA

Security of stored data
Unlimited