Home Gas Analyzer Indonesia Model 313 Portable NOx Flue Analyzer (NOVA)
Model 313 Portable NOx Flue Analyzer (NOVA)

In operation, a built-in sample pump draws in the gas sample through the S.S. probe, 12 ft sample hose, condensate removal filter, secondary filter and flowmeter, then on to both sensors. The output of each sensor is then amplified and displayed on a large LCD digital meter with backlight. A selector switch allows the two gases to be read individually or as a total (NOX). The rechargeable battery provides enough power for about 20 hours of continuous operation and the analyzer can be used while it is being recharged. A red LED tells when to recharge and a green LED verifies that it is receiving recharging power. The recharger plus a stainless steel probe with 12 ft. (4 m) hose is included.

APPLICATIONS
Analysis of oxides of nitrogen (NOX) such as nitric oxide (NO) and/or nitrogen dioxide (NO2). For boiler, furnace, or engine exhaust monitoring and analysis.

FEATURES
• NOX can be read as NO, NO2, or as total
• Rugged design that is easy to operate
• Disposable, long life electrochemical NO and NO2 sensors
• Digital meter readout with backlight
• Modular layout that is easy to maintain
• Rechargable battery operation
• Built-in sample pump, filter, and flowmeter
• Active condensate removal
• Rapid reading recovery after NOX 'overdose'
• Weatherproof (WP) cabinet with clear Lexan cover
• Stainless steel probe with sample hose

OPTIONS
• Recorder outputs of 0-1V or 4-20 mA (can be isolated)
• Stack temperature readout (313T)
• Special sampling probes
• Sample pre-cooler
• Suitcase (K) style cabinet available
• AC power only operation
• NO, NO or NOx alarms with LED
• Detachable/portable data logger

CALIBRATION
• Air for zero.
• Analyzed calibration gas mixtures of PPM NO and PPM NO2 in nitrogen for span.

SPECIFICATIONS

Description
Method of Detection: Customer replaceable electrochemical nitric oxide and nitrogen dioxide sensors
Expected life 2-3 year each
Ranges Available: 0-2000 PPM NO; 0-800 PPM NO2; 0-2000 PPM NOX (0-5000 PPM available)
Ranges switch selectable
Resolution: 1 PPM on 0-2000 PPM; 10 PPM on higher ranges
Accuracy and Repeatability: Better than 2% full scale
Drift: Within 1% of full scale per 8 hours of continuous operation
Response Time (T-90): 20-30 seconds
Ambient Temperature Range: 55° to 120°F (12° to 49°C)
Linearity: ± 2% of full scale
Size and Weight: WP style - approx. 11½" L x 8" W x 7¼" H @ 8 lbs (29 x 20 x 18 cm @ 3.6 kg)
K style - approx. 14" L x 10½" W x 6" H @ 12 lbs (36 x 27 x 15 cm @ 5.5 kg)
Power: AC/DC operation. 115VAC 60Hz for recharging (other voltages available)
Output Options: 4-20 mA or 0-1 VDC
 
Equipment has always been an important part, having equipment that is technologically advanced gas analyzer can make the job easier. In terms of precision gas analysis, and the accuracy of the data becomes very important, therefore we as a supplier of gas analyzer Indonesia equipment very understanding so we always give priority to products that have the precision and accuracy of the data from the gas analyzer.