In operation, a built-in sample pump draws in the gas sample through the S.S. probe, 12 ft sample hose, condensate removal filter, secondary filter and flowmeter then on to the NO sensor. The detected NO is displayed on a LCD digital meter which has a switchable backlight for use in dark areas. The rechargeable battery provides enough power for about 20 hours of continuous operation and the analyzer can be used while it is being recharged. A red LED tells when to recharge and a green LED verifies that it is receiving recharging power. The recharger is included.

APPLICATIONS
Analysis of oxides of nitrogen (NOX) as nitric oxide (NO) in boiler, furnace, or engine exhaust.

FEATURES
• Rugged design that is easy to operate and maintain
• Fast warm-up and response
• Disposable, long-life electrochemical NO sensor
• Digital readout meter with backlight
• Modular layout that is easy to maintain
• Rechargeable battery operation
• Built-in sample pump, filter and flowmeter
• Continuous condensate removal
• Rapid recovery on NOX overdose
• Stainless steel probe with sample hose

OPTIONS
• Recorder outputs of 0-1V or 4-20 mA
• Stack temperature readout (312T)
• Special sampling probes
• Sample pre-cooler
• Suitcase (K) style cabinet available
• AC power only operation
• NOX alarms with LED
• Detachable/portable data logger

CALIBRATION
• Air for zero
• Analyzed calibration gas mixture of PPM NO in air for span.

SPECIFICATIONS

Description
Method of Detection: Customer replaceable electrochemical NO sensor
Ranges Available: 0-2000 PPM NOX (as NO)
Resolution: 1 PPM
Accuracy and Repeatability: Better than 2% full scale
Drift: Within 1% full scale per 8 hours of continuous operation
Response Time (T-90): 20-30 seconds for 90% step change
Ambient Temperature Range: 55° to 120°F (12° to 49°C)
Linearity: ± 2% of full scale
Size and Weight: WP style - approx. 11½" L x 8" W x 7¼" H @ 8 lbs (29 x 20 x 18 cm @ 3.6 kg)
K style - approx. 14" L x 10½" W x 6" H @ 12 lbs (36 x 27 x 15 cm @ 5.5 kg)
Power: AC/DC operation. 115VAC 60Hz for recharging (other voltages available)
Output Options: 4-20 mA or 0-1 VDC
 
Equipment has always been an important part, having equipment that is technologically advanced gas analyzer can make the job easier. In terms of precision gas analysis, and the accuracy of the data becomes very important, therefore we as a supplier of gas analyzer Indonesia equipment very understanding so we always give priority to products that have the precision and accuracy of the data from the gas analyzer.